USG

Power Module with Built-in GFCI
OJ Microline® intuitive Power Module with built-in GFCI
In large applications, UCG, UDG and UTN thermostats can be extended with additional USG power modules with built-in Class A GFCI. Output can thus be increased by 15 A per module.
EFFICIENT, INTUITIVE AND STYLISH
-
Easy to use with no need for use of manual
-
Screw terminals for safe and easy installation
-
Multi voltage: 120 - 240 V (incl. 208 V)
-
Output relay: 15 A
-
Class A GFCI: suitable for wet room installation
-
Industrial Design:
USA - Design Patent No. D768092
Canada - Design Patent No. 161353
-
Product Sheet
-
Guide
-
Brochure
-
Where to connect the ground wire of floor mats?
Reply
The ground wire in the floor mat must be connected directly to the ground wire of the supply.
-
What is the recommended night setback?
Reply
The recommended night setback is max 5°C/41°F
-
Does the adaptive function reset when making a factory reset?
Reply
Yes the adaptive function is reset during a factory reset.
-
Installation – Length of sensor cable
Question
What is the maximum length of the sensor cable?
Answer
In general, it is recommended that the maximum sensor cable length should be 164 feet/50 meters, the length might be shorter. Read the instructions for the precise maximum length.
-
How can I cure the E2 error message?
Reply
"E2" means defective, damaged or disconnected floor sensor. Sensor resistance should be 10 or 12 kOhm at 25°C (77°F). The onstruction or quick guide holds informatiom for the specific thermostats.
Наша

Создание Ноу-хау: Мы используем наши знания и опыт, чтобы найти правильное решение.
Новости

Найти последние новости о продукции электрического обогрева пола компании OJ Electronics можно найти здесь.
Экономия

Интеллектуальные системы управления создают максимальный комфорт при низком потреблением энергии.
Свяжитесь с

Диалог и тесное сотрудничество -кратчайший путь к идеальному решению всех проблем.