UTN (Discontinued)

Non-Programmable Thermostat with Built-in GFCI
OJ Microline® intuitive Non-programmable OJ Microline thermostat with built-in GFCI. Optimal comfort in controlling electrical underfloor heating. Built-in effciency, intuitive operation and with a stylish design
EFFICIENT, INTUITIVE AND STYLISH
* Industrial Design:
USA - Design Patent No. D633445
Canada - Design Patent No. D130878
-
Simple user interface and thoughtful installation design
-
Easy to use with no need for use of manual
-
Screw terminals for safe and easy installation
-
Multi voltage: 120 - 240 V (incl. 208 V)
-
Output relay: 15 A
-
Large back-lit display for easy reading
-
Class A GFCI: suitable for wet room installation
-
Product Sheet
-
User Manual
-
Instructions
-
What is the backup time?
Reply
The program settings are permanent, the clock will be reset after 2 to 4 hours.
-
How to unlock the child lock?
Reply
- From the home screen
-
Press "OK" button twice
-
Press button UP and DOWN simultaneously for 3 sec.
-
Unlock Child Lock (MP4)
- From the home screen
-
What does error code "E2" mean?
Reply
Error code "E2" means defective, damaged or not connected floor sensor. Check connections or replace sensor if necessary.
-
What causes the led to be permantly ON?
Reply
Your heat mat or installation between thermostat and heat mat has a fault current to ground. The thermostat has cut off the power for your safety. Please contact your local electrician.
-
How to make the USG switch off when the thermostat does?
Reply
Check the connections between the two units. If the USG is connected incorrectly to the thermostat, the USG won't switch off.
-
Where to connect the ground wire of floor mats?
Reply
The ground wire in the floor mat must be connected directly to the ground wire of the supply.
-
What is the recommended night setback?
Reply
The recommended night setback is max 5°C/41°F
-
Does the adaptive function reset when making a factory reset?
Reply
Yes the adaptive function is reset during a factory reset.
-
Installation – Length of sensor cable
Question
What is the maximum length of the sensor cable?
Answer
In general, it is recommended that the maximum sensor cable length should be 164 feet/50 meters, the length might be shorter. Read the instructions for the precise maximum length.
-
How can I cure the E2 error message?
Reply
"E2" means defective, damaged or disconnected floor sensor. Sensor resistance should be 10 or 12 kOhm at 25°C (77°F). The onstruction or quick guide holds informatiom for the specific thermostats.
Наша

Создание Ноу-хау: Мы используем наши знания и опыт, чтобы найти правильное решение.
Новости

Найти последние новости о продукции электрического обогрева пола компании OJ Electronics можно найти здесь.
Экономия

Интеллектуальные системы управления создают максимальный комфорт при низком потреблением энергии.
Свяжитесь с

Диалог и тесное сотрудничество -кратчайший путь к идеальному решению всех проблем.